| TC 44 | TC 66 | TC88 | |
|---|---|---|---|
| description | highly operational simplified programme controller for ceramic applications, very easy to learn and understand, more advanced alternative to analog controls | compact and powerful programme controller for all applications in ceramics, flexible firing curve, adjustable programmes, very easy to use, best buy for feature and price | compact and powerful programme controller for applications requiring a fully flexible firing curve (e.g. glass fusing, D & R) etc.; multiple heating, dwelling and cooling segments |
| firing curve | First ramp selectable 60/120/240/360/480 °C/h or full-on (100%) to fixed setpoint 580°C, Second ramp full-on (100%) to adjustable top temperature 400°C-1320°C (in 5°C steps), Dwell adjustable (0/10/20/30/60 min) |
Delay Start 0:00-10:00 hours, First ramp 5°C/h to 999°C/h or full-on to adjustable first setpoint, Second ramp 5°C/h to 999°C/h or full-on to adjustable second setpoint, Dwell 0:00-10:00 hours, Cooling Ramp 5°C/h to 999°C/h |
Any shape of the firing courve: Delay Start 0:00- 10:00 hours, up to 9 ramps (as heat up, dwell or cooling ramp), on each ramp adjustable time (0:00 to 10:00 hours) and temperature (20°C to maximum kilns temperature) |
| programmes | 1 (set programme will be saved) | 6 user definable programmes | 3 user definable programmes Option -E: 20 programmes |
| displays | 4-digit LED, firing curve | 4-digits LED, firing curve, units | 4-digits LED, 2-digits segment number, 5x7 LED dot matrix for segment profile |
| safety features | self-test, optional drive of 2nd power relay thermocouple break and short -circuit |
extended self-test, optional drive of 2nd power relay thermocouple break and short-circuit self-test of the acquisition input |
extended self-test, optional drive of 2nd power relay thermocouple break and short-circuit self-test of the acquisition input |
| error messages | • | • | • |
| error logbook | - | • | • |
| accuracy / control type | 0,4% / PID | 0,2% / PI/PID | 0,2% / PI/PID auto tune |
| EMC accord. IEC 801 IV | • | • | • |
| mains supply | 85-264V AC/DC | 85-264V AC/DC | 85-264V AC/DC |
| approvals | CE | CE | CE |
| dimensions in mm | 80 x 153 x 22 | 80 x 153 x 22 | 80 x 153 x 22 |
| weight (w/o plug) | 340 g | 340 g | 350 g |